- Nursing procedures for the insertion of a subclavian catheter (Mahoker)

steps

·      Routine hand washing

·      Preparing instruments and tools

1.    cath-set

2.    syringe

3.    adhesive tap

4.    beta dine ( surgical )

5.    lidocaine

6.    surgical gloves

7.    suture

8.    S.T sponge

9.    Kidney basin 

▪️ Explaining the procedure in a simple way helps with the patient's psychological motivation.

▪️   Surgical hand washing.

▪️  Helping the doctor sterilize the installation site.

▪️   Helping the doctor to administer Xylocaine at the insertion site.

▪️Follow up on transferring the patient to the radiology department for a chest X-ray by the staff after the procedure.

▪️  The X-ray was shown to the doctor to monitor the catheter's location.

▪️   Helping the doctor in securing the catheter.

▪️  Administering a heparin ampoule is done according to the doctor's orders in the arteriovenous fistula after the session ends.

▪️  Changing the location of the mahoker.

▪️ Washing hands is routine.