Steps :
· Handwashing
· Preparing the necessary supplies (bandage + sterile gauze)
· Wearing protective clothing (apron - gloves - mask - goggles)
· Measuring blood pressure before ending the session to determine the type of solution used, saline or glucose.
· Closing the blood pump and closing the artery valve and artery needle
· Placing the arterial line in the solution bottle and opening the blood pump.
· Activating the connections and filter to ensure that blood does not clot in the filter.
· Raising the arterial-venous fistula needle and applying gentle pressure on it.
· Disinfect the arteriovenous fistula site with Betadine, sterile gauze, and a plaster after ensuring there is no blood at the fistula site.
· Disposing of connections, filters, and all patient-related consumables, and changing the bedding.
· Disinfecting the machine from the outside with chlorine and alcohol
· The patient's weight and recording it in the medical file.
· Measuring blood pressure before allowing the patient to leave the unit
· Recording all supplies and medications and obtaining the signatures of the responsible nursing staff
· Following up on the patient's signature for the session and confirming the time for the next session.
· Monitoring the patient's discharge from the unit by the staff.